<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-13 08-19-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.10 MHz 5/5, 57 dBuV F I P
Pilot RDS Phase Difference
6.9 kHz 3.5 kHz 66 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 73 kHz 10040 0,1096
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
2,7 dBr 4,03 dBr 4,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" F I P " F204 0 (No PTY) 1 0 1 1 8:19, 13.05.2025
RT
"MATRINITE - CONTREBANDE (2025) - FIP "
AF EON
92.3, 101.2, 105.1 MHz F201, F203, F208, F222
FM Scope Station: 105.10 MHz, signal: 4/5 (58 dBuV) Max at: 73 kHz MIN: 11 kHz % above 76 kHz: 0,1096 Acquired: 2025/05/13 8:18:06 Total samples: 10040 Equivalent time: 0:08:22 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,7 dBr MIN: 2,7 dBr AVE: 4,03 dBr % above 10,2 dBr: 0,0 Last value: 3,7 dBr (2025/05/13 8:18:06) Station: 105.10 MHz, signal: 5/5 (57 dBuV) 08:11 08:12 08:13 08:14 08:15 08:16 08:17 08:18 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality